📦 Full Set: ready-to-run bundle
- LOAD CONTROLLER with motor cable ×1
- T-METER tachometer for use with the SKW-0003 motor holder ×1
- LOADER for loaded break-in ×1
- Thai and English instruction manual ×1
- SKW-0003 aluminum motor holder ×1
- 12VDC 7A (84W) AC adapter ×1
REG PLANNING – LOAD CONTROLLER (Produced by Shige)
Designed by Shige for Mini 4WD motor measurement, testing and break-in, from detailed break-in settings to load-based simulations of running conditions.
🔥 Features
- Supports both no-load and loaded motor break-in.
- Measures maximum speed (rpm), current (A) and power (W).
- LOAD Mode simulates running loads, with a maximum load setting of 4,000.
- Preset + Cycle functions for repeat testing.
- Shige's Flick / Pulse Break-in alternates voltage during break-in. Motors may become hot; supervise operation.
- For selecting motors before a race and exploring motor characteristics.
⚙️ Main functions
① No Load Break-in
Fine settings for preparing the brush–commutator contact surfaces without an external load.
Available settings
- Voltage: 0.1–3.0V
- Current: 0.01–9A
- Power: 0.01–20W
- Speed: 100–90,000 rpm
- Time: up to 24 hours
- Direction: L / R
- Presets: 10 patterns × 2 sets
- Cycle: 1–999 cycles
Flick: automatic voltage alternation
Example: 1.5V for 15s → 1.0V for 10s (up to 99s).
Uses and precautions
- Study changes in motor behavior during break-in.
- Check motor condition before use.
- Motors may become hot during operation. Do not leave the device running unattended, and stop if abnormal heat occurs.
- Prepare motors before racing.
② With Load Break-in
Connect the LOADER to simulate operating conditions under load.
Additional loaded-operation settings
- Adjust the Load Value.
- According to manual mlcv1.2, in FLICK mode at 6W or above, STD (the duration of the lower-voltage interval) has a minimum of 15 seconds. This is not an automatic motor-stop cooling period.
- Explore motor settings under simulated running loads without going to the track.
③ No Load Measurement
Two modes:
- Memory Mode (measurement within a preset)
- One-time Mode (single measurement)
Displays:
- Maximum speed (rpm)
- Current (A)
- Power (W)
④ LOAD Mode: measurement under simulated running loads
For comparing motors intended for racing.
Available settings
- Load: 1–4,000 (commonly used range stated in the shop description: 1,700–2,300)
- Rotation direction
- Power
- Measurement duration
- Straight/curve ratio to simulate track layout
Measurement sequence
- Standby for 15 seconds.
- Measure for the selected duration.
- Display voltage, current, power and speed calculated for the load.
Additional function
- Set gearing, wheel size and track length to calculate estimated time/speed.
Uses
- Compare motors under simulated running conditions.
- Compare behavior at high speed and under load.
- Test at home without visiting the track.
🔧 Important Flick / Pulse Break-in information
This function alternates voltage during break-in. It is intended for users who understand motor settings. Supervise operation because motors may become hot. Do not leave the device running unattended.
🎯 Intended users
- Racers comparing motors for competition
- Racers simulating running loads at home
- Shops or break-in service providers
- Advanced motor setup developers
📌 Summary
REG PLANNING LOAD CONTROLLER by Shige combines motor break-in, measurement and load simulation for comparing and preparing Mini 4WD motors.
Reference for heat warnings and STD settings: REG Planning LOAD CONTROLLER mlcv1.2 Japanese manual, pages 7 and 10






















